Mitsubishi Electric MSZ-GX mini-split error codes

On the MSZ-GX series you can read the unit's error code from the remote controller while the left or upper operation-indicator lamp on the indoor unit is blinking. The manual tells you to stop using the air conditioner, turn off the breaker and contact your dealer when the unit has an error.

What this table coversRemote-controller error codes from the "Error Code Display Mode" page of the MSZ-GX / MUZ-GX (A2L series) operation manual. Other Mitsubishi lines use different codes and LED blink patterns.

How to read the display

With the remote controller off, point it at the indoor unit and hold CHECK with a fine-tipped object. "00" is shown. Keep pointing until the indoor unit beeps.

When the display shows 00: two beeps means the unit has no error, and one beep means the unit has an error. Then press the up or down buttons to step through codes in order from 00 and E6 up to UP.

For each code, two beeps from the indoor unit means the unit has the error for the code shown. One beep means no error for that code, so keep stepping. No beep means the diagnosis failed, so try again.

Pressing other buttons cancels the error code display. If the remote is operated while the lamp is not blinking, the code shown might not be accurate.

Mitsubishi Electric code table

CodeMeaningWhat the document says
E6 / E7 Indoor unit: serial signal
EE Indoor unit: inconsistency of the indoor unit and outdoor unit's refrigerant
Fb Indoor unit: indoor control system
FH Indoor unit: refrigerant sensor of the indoor unit
FL Indoor unit: refrigerant leakage abnormality of the indoor unit; abnormality related to the refrigerant sensors for the other indoor units when multiple indoor units are connected
P1 Indoor unit: room temperature thermistor
P2 / P9 Indoor unit: indoor coil thermistor
P4 Indoor unit: drain sensor
Pb Indoor unit: indoor fan motor
E8 / E9 / EC Outdoor unit: indoor/outdoor communication, receiving error
FC Outdoor unit: nonvolatile memory data
Fd Outdoor unit: different voltage
P8 Outdoor unit: 4-way valve / pipe temperature
PL Outdoor unit: outdoor refrigerant system
U3 Outdoor unit: discharge temperature thermistor
U4 Outdoor unit: defrost thermistor, fin temperature thermistor, P.C. board temperature thermistor, ambient temperature thermistor or outdoor heat exchanger temperature thermistor
UE Outdoor unit: stop valve (closed valve)
UP Outdoor unit: outdoor power system

Source: Mitsubishi Electric MSZ-GX operation manual, error code table (page En-18). Rows are grouped as in the manual: indoor unit codes first, then outdoor unit codes. H6 does not appear in this table.