Navien NPN tankless water heater error codes
Navien shows an E-prefixed error code on the front panel. The manual's chart gives a reason and a self-diagnostic action for each one, and for many codes the action is simply to contact technical support.
What this table coversCodes from section 5.2 of Navien's NPN non-condensing water heater User's Information Manual. Condensing Navien models use different manuals.
How to read the display
The code appears on the front panel. Some codes (like E003) have a few safe owner checks. Others say only to contact technical support, which you should do rather than opening the unit.
Navien code table
| Code | Meaning | What the document says |
|---|---|---|
| E003 | Ignition failure | Ensure the main gas supply valve is open. Ensure the gas manifold and the fuel DIP switch setting match the supplied gas type. Full explanation |
| E004 | False flame detection | Ensure the electrical cord is properly grounded. |
| E012 | Flame loss | Clean the intake air filter. Ensure the electrical cord is properly grounded. Ensure the gas manifold and fuel DIP switch setting match the supplied gas type. |
| E016 | Overheating of heat exchanger | Turn the system off for at least 30 minutes, then restart it. Clean the cold water inlet filter. Flush the heat exchanger. |
| E046 | Abnormal operation: limit control | Contact Navien technical support. |
| E056 | Abnormal operation: modulating gas valve | Contact Navien technical support. |
| E109 | Abnormal operation: fan motor | Contact Navien technical support. |
| E110 | Abnormal air pressure | Ensure the vent pipe is free of obstructions. Full explanation |
| E127 | Abnormal operation: air volume open / short / default value / no answer | Contact Navien technical support. |
| E157 | Abnormal operation: air volume control | Contact Navien technical support. |
| E170 | Antifreeze heater open / short | Contact Navien technical support. |
| E407 | Hot water outlet: thermistor open or short circuit | Contact Navien technical support. |
| E421 | Cold water inlet: thermistor open or short circuit | Contact Navien technical support. |
| E434 | Abnormal operation: water adjustment valve | Contact Navien technical support. |
| E438 | Abnormal operation: circulation pump | External: ensure all water supply and return lines are open. |
| E439 | Abnormal operation: flow sensor | Contact Navien technical support. |
| E441 | Hot water inlet: thermistor open or short circuit | Contact Navien technical support. |
| E445 | Abnormal operation: bypass mixing valve | Contact Navien technical support. |
| E515 | Abnormal operation: PCB | Ensure the electrical cord is properly grounded. |
Source: Navien NPN User's Information Manual, chart in section 5.2.
Detailed explanations
- Navien tankless water heater error E003: ignition failure
- Navien tankless water heater error E110: abnormal air pressure
SafetyThese tables describe what the manufacturer documents say. Gas, combustion, refrigerant and line-voltage repairs are for licensed professionals. If you smell gas, leave the building and call your gas utility or 911. Safety disclaimer.
Sources
- User's Information Manual: NPN Non-Condensing Water Heaters, section 5.2 Understanding Error Codes (Navien) Covers: Navien NPN-series non-condensing tankless water heaters (NPN-120E through NPN-199U). Condensing NPE/NCB models have their own manuals.