Rheem tankless water heater error codes
Rheem's troubleshooting manual separates warning codes (the heater keeps running) from error codes (the heater stops). The manual sends you to the gas supply, vent and flame rod first for ignition problems.
What this table coversTitles from the table of contents of the Rheem High and Super High Efficiency Tankless Water Heater Troubleshooting Manual (AP21822 Rev 02).
How to read the display
Codes show on the built-in controller or the remote controller. The manual lists the last eight faults in the controller's error history, which helps when a code comes and goes.
Several codes in the manual are marked "WiFi model only". Check that your model is in the list at the front of the manual.
Rheem code table
| Code | Meaning | What the document says |
|---|---|---|
| P1 | Error: not enough water flow for operation | |
| 1L | Warning: lime build-up detected in heat exchanger | |
| 03 | Error: manifold setting failure | |
| 05 | Warning: low heat exchanger temperature detected | |
| 28 | Error: low heat exchanger temperature detected | |
| 10 | Warning: incorrect inlet air volume | |
| 11 | Error: flame not detected by flame rod | Full explanation |
| 12 | Error: detected presence of flame, then lost it | |
| 14 | Error: over-heat limiter is active | |
| 15 | Error: excessively hot water detected | |
| 16 | Error: outlet thermistor failure | |
| 17 | Error: water leak detected (WiFi model only) | |
| 24 | Error: DIP switch malfunction | |
| 29 | Error: condensation not drained from collector | |
| 31 | Error: inlet thermistor malfunction | |
| 32 | Error: heat exchanger thermistor malfunction | |
| 33 | Error: outlet thermistor malfunction | |
| 34 | Error: ambient / air supply thermistor malfunction | |
| 35 | Error: improper thermistor connection | |
| 51 | Error: main gas solenoid valve (SV) malfunction | |
| 52 | Error: proportional gas valve malfunction | |
| 61 | Error: blower motor speed incorrect for combustion | |
| 66 | Error: bypass motor failed | |
| 70 | Error: microcomputer abnormality | |
| 71 | Error: solenoid valve (SV) circuit failure | |
| 72 | Error: flame rod detected flame before ignition | |
| 76 | Error: built-in display (or remote controller) to water heater communication failure | |
| 79 | Error: blower motor current failure | |
| 80 | Error: detected flame presence after closing solenoid valves | |
| 82 | Error: installed gas chip error | |
| 88 | Maintenance notice | |
| 89 | Error: high exhaust temperature detected | |
| 90 | Error: blockage in venting detected (before the unit goes to ignition) | |
| 99 | Error: blockage in venting detected (after the unit shut down) |
Source: Rheem AP21822 Rev 02, section 2.2 error code list.
Detailed explanations
SafetyThese tables describe what the manufacturer documents say. Gas, combustion, refrigerant and line-voltage repairs are for licensed professionals. If you smell gas, leave the building and call your gas utility or 911. Safety disclaimer.
Sources
- High and Super High Efficiency Tankless Water Heater Troubleshooting Manual (AP21822 Rev 02) (Rheem) Covers: Rheem high and super high efficiency tankless water heaters (condensing and non-condensing, indoor and outdoor) covered by this manual.